MFG #T153005
UPC #04750308534
SKU #19921
Product description
ACME T153005 .10KVA1PH 240/480-120/240 TFMR
Acme Electric® Distribution Transformer, Air Colled/Dry, 240/480 VAC Primary, 120/240 VAC Secondary, 0.1 kVA, 50/60 Hz, 1 ph, 0.6/1.2/2.4 A Maximum, Wire Lead, Wall Mount, Class B/130 deg C, NEMA 3R, 115 deg C, 3.67 in L x 3.89 in W x 7.16 in H
Acme Electric® Distribution Transformer, Air Colled/Dry, 240/480 VAC Primary, 120/240 VAC Secondary, 0.1 kVA, 50/60 Hz, 1 ph, 0.6/1.2/2.4 A Maximum, Wire Lead, Wall Mount, Class B/130 deg C, NEMA 3R, 115 deg C, 3.67 in L x 3.89 in W x 7.16 in H
- Quiet operation with sound levels well below NEMA standards
Electrostatic shield for enhanced protection
Encapsulated core and coil
Long life UL class 130 deg C insulation system, transformers can be banked for 3-phase service
Large wiring compartment, no conduit or pull boxes required, front access for wiring ease, wiring compartment remains cool
Completely enclosed UL-3R enclosure for indoor/outdoor service, rugged non-ventilated construction
Plenty of knockouts for multi-directional entry
All copper lead wire terminations
Air cooled/dry cooling
Four windings
Aluminum, two primary winding, two winding secondary
Easy and convenient installation to meet your requirements, the transformer can be mounted in any position
Plenty of knockouts for multi-directional entry, all copper lead wire terminations
1.2 A for 240 VAC, 0.6 A for 480 VAC primary, 2.4 A for 120 VAC secondary
- Product Catalog Page(s)
MSDS
Specification Sheet
- UL 506|E79947V1|50B8|B3223|CSA Certified|OSHA Approved|ANSI Specified|IEEE
- TRANSFORMER DISTRIBUTION 240/480VAC 60HZ
- Harsh Industrial Locations, Corrosive Chemical Exposure and Waste Water Treatment Facilities
- Acme Electric Distribution Transformer, Air Colled/Dry, 240/480 VAC Primary, 120/240 VAC Secondary, 0.1 kVA, 50/60 Hz, 1 ph, 0.6/1.2/2.4 A Maximum, Wire Lead, Wall Mount, Class B/130 deg C, NEMA 3R, 115 deg C, 3.67 in L x 3.89 in W x 7.16 in H
- Brand: Acme TransformersConnection: Wire Lead Screw TerminalCooling: Air Cooled/DryCountry of Origin: CNEnclosure: NEMA 3R SteelFrequency Rating: 50/60 HzFuse Rating: Primary: 1.2 AMP For 240 V, 0.6 AMP For 480 V, Secondary: 2.4 AMP For 120 VHeight: 7.16 inLength: 3.67 inMounting: WallPhase: 1Primary Voltage: 240 X 480 VSecondary Voltage: 120/240 VStandard: UL 506|E79947V1|50B8|B3223|CSA Certified|OSHA Compliant|ANSI Specified|IEEETemperature Rating: 115 DEG C RiseType: Distribution TransformerWidth: 3.89 inWinding: Aluminum, Configuration: Primary - Two Winding, Secondary - Two Winding